How To Maintain The Mask Equipment?

- May 28, 2020-

It is very important to buy the mask equipment for maintenance. The main maintenance is done properly. The equipment is also smooth during operation. The masks produced meet the standards, and the details have a large impact area. Here's how to check common problems and solutions:


1. Appearance:


Folding mask machine


Masks are what we wear on our faces, and some even need to be used in the operating room, so the production of masks requires a mask machine to be cleaned every day. You can arrange personnel to clean the work surface of the equipment and the dishes containing the masks after shutting down the power supply every day. Be careful not to use water or oil. You can also use alcohol and other non-toxic and volatile cleaning fluids. Folding mask machine manufacturer


2. Ultrasonic system:


Check whether the ultrasonic system is clean, especially the ultrasonic electric box, ultrasonic transducer and welding head must be cleaned monotonously without water, and the connection line is robust. Often check the degree of wear of the ultrasonic welding head (mold). Check carefully whether the pointers of the voltmeter and ammeter on the ultrasonic electric box are normal.


3. Transmission system:


The transmission system includes motors, gears, speed reducers, sprockets, chains, conveyor belts and other components. Mask machine protection needs to check whether the surface of the motor has dust and other things that affect heat dissipation. Whether the gears and sprockets are oiled or attached. Is the chain tightness suitable for foreign matter? Is the connecting screw of each transmission part loose? Is the lubricating oil of the reducer sufficient? Usually, it is necessary to replace the lubricating oil every 1000 hours to 1500 hours. Folding mask machine manufacturers


4. Electrical system:


Check whether the circuit connector of the mask machine is loose, whether the main power cord and branch signal line are worn? Aging? Loose? Is the electric box clean and monotonous, is the exhaust fan working normally?


Five: pneumatic system:


Does the air filter check for water? Check the air pipe for air leaks? Cylinder for air leaks? Cylinder magnetic anti-sensor orientation and operation are normal.


In addition: the device must not touch corrosive liquids and objects, for example: sweat is very simple and causes parts of the device to rust. If the equipment is not used for a long time, apply anti-rust oil to the transmission system and rusty parts of the mask machine.


These are what we need to do after purchasing the mask equipment, so that the mask equipment can work for us for a long time. Folding mask machine